Enter a temperature wet bulb and actual station pressure.
Relative humidity calculator wet bulb dry bulb.
This script will determine the relative humidity from the entered dry and wet bulb temperatures data.
Relative humidity dewpoint temp c results.
At 100 relative humidity the wet bulb temperature is equal to the air temperature dry bulb temperature.
Relative humidity is measured using a device called a sling psychrometer this consists of 2 side by side conventional thermometers one of which the wet bulb thermometer has a wetted wick placed at the bottom the other the dry bulb thermometer has no wetted wick.
Enter your actual station pressure not the altimeter setting.
Dry bulb temperature t db can be measured with a simple thermometer as shown above.
Calculate dewpoint wet bulb temperature from relative humidity.
If the air is fully saturated 100 relative humidity the water cannot evaporate so both the wet and dry bulb temperatures are the same.
Note that continuously air flow around the thermometer is important to evaporate.
There is a converter below this calculator if you only know the celsius temperature for the entries required.
By definition wet bulb temperature is the lowest temperature a portion of air can acquire by evaporative cooling only.
Enter the two different temperatures.
Wet bulb temperature t wb can be measured with a standard thermometer with some wet clothing cotton or similar around the bulb.
Dry bulb temp c.
Air humidity can be estimated by measuring.
Enter dry bulb temperature plus either wet bulb temp rh or dewpoint temp.
The entry required is in fahrenheit degrees.
Dewpoint is the atmospheric temperature below which water droplets begin to condense and become dew.
Enter your actual station pressure not the altimeter setting.
Wet bulb temp c.
When the psychrometer is swung around by its attached chain or handle the air causes the water on the wick to evaporate which.
A simple online weather calculator to find the dewpoint and the wet bulb temperature by knowing the values of relative humidity temperature and actual station pressure.
Dry bulb temperature and.
It includes a dry bulb thermometer a wet bulb thermometer and a psychrometric chart a graph that plots the relationships between the dry and wet bulb temperature relative humidity and dew point at constant pressure.
If the dry and wet bulb temperatures are set to the same value the calculator will show the saturation mixing ratio the amount of water in saturated air at that temperature.
In of mercury mm of mercury millibars hpa.
The wet bulb temperature wbt is the temperature read by a thermometer covered in water soaked cloth wet bulb thermometer over which air is passed.